Enter Applicant Contact Information: |
|
||||||||||||||||||||||||||||||||
Are you the Property Owner? | No |
Property Owner Contact
Property Owner Email: | sakirkhoff@msn.com | ||||
Property Owner Phone: |
|
Property Location
Property Location: |
|
Enter directions to the property (if no property address assigned): | 169 S to 450th Ave (south of Round Lake); right on 450th to 221XX 450th Avenue. |
Project Checklist
1.) Is the property zoned Shoreland? | Yes |
3.) Are there any wetlands or lowlands on/near the project site? | No |
4.) Will the structure(s) be used for commercial purposes? | No |
5.) Is there an existing septic system on the property? (Outhouse/Privies are also considered septic systems) |
No |
6.) Are you applying to install a new septic system? | Yes |
Septic Type
Select the type of septic you are applying for: | Residential Other/Performance (Type 3) Residential Operating Permit (Type 3, 4, 5) |
Design Information
Attach Septic Design & Management Plan: | |
Septic Designer: |
None
|
Operating Permit
Attach the Operating Permit Application & Operating Permit Maintenance Contract: |
|
Pumping Agreement
Attach Pumping Agreement: |
Installer
Self Install or Licensed Install: | Licensed Septic Installer |
Licensed Installer Name: |
None
|
Installer License # : | 747 |
Project Description
Please describe your proposed project: | New residential custom construction home with a small 6.0' tall crawl space beneath, covered entry, attached sun/screen porch, attached garage, wood burning fireplace in living area, 3 bedroom, 2 bath. Footprint is 2,139 square feet |
What is the height of your structure? | 27 Feet |
Project Type
Item 1 - Structure Type: | New Residence incl. attached decks/porches/garages |
Item 1 - Size: | 2582 ft2 |
Shoreland Data
Setback distance from Ordinary High Water Level to the proposed construction? (closest point) | 110 Feet |
Will the proposed structure(s) be less than 35 foot maximum height? | Yes |
Are you constructing a walkout basement? | No |
If you are building an accessory structure, will there will be a loft or second story? | No |
Natural Landscape Protection Plan
Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? | No |
How many cubic yards of fill or excavation will be done on the property? | 50 CuYd |
How close to the property line will any fill be placed or any excavation be done? | 20 Feet |
What percent slope of the land currently exists on the project site? | 1 % slope |
Select the erosion control methods that will be used throughout and after your project: (Check all that apply) |
|
6.) What will be done after construction to control erosion? |
Landscaping to include proper runoff, grass around structure and gutters |
Site Plan
Attach Site Plan: |
|
Is the site staked and ready for inspection? | Yes |
Terms
All appropriate permit fees must be paid in full prior to any necessary review(s) of application.
It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.
The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.
Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).
All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.
Permit fees are non-refundable after a permit has been approved.
The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.
Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."
Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.
Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.
Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.
I acknowledge that by submitting this application, the application and its attachments are public information.
Invoice #56361 (10/20/2022)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 10/13/2022 2:48 PM $550 Flat Fee |
$550.00 | x 1 | $550.00 |
added 10/14/2022 10:58 AM $150 Flat Fee |
$150.00 | x 1 | $150.00 |
added 10/14/2022 10:58 AM $400 Flat Fee |
$400.00 | x 1 | $400.00 |
Grand Total | |||
Total | $1,100.00 | ||
Payment 10/13/2022 | $1,050.00 | ||
Payment 10/14/2022 | $50.00 | ||
Due | $0.00 |
Approvals
Approval | Signature |
---|---|
Applicant | Jon Fogarty - 10/20/2022 8:54 AM c353d26da23e734e175f6a024d8c9721 6d273a0bfcc1415c4306b45b3ea7e6f1 |
#1 Adminstrative Approval Group | Shannon Wiebusch - 10/20/2022 3:32 PM 7078dec09f616605b77f3be991b70d3a 05d545ac5966708c88f75caf500447e7 |
#2 Inspector Group | Connor Plagge - 10/25/2022 9:40 AM a44f27f8ec30c83c549577bc91a84a13 a8957c46c116d799c423fabc4036e77d |
#3 Level Three Final Action | Kim Burton - 10/25/2022 11:30 AM dcac80981a2d2ddd89e36de6b8b5a59d ea6db84bda816a51ae287ddf1caf7fb4 |
Public Notes
Text: | Permit # 47429. Approved for a 2582 sq ft New Residence incl. attached decks/porches/garages and a 3 bdrm Type III mound septic with operating permit #813 and one condition; 1. Event counter or other flow measuring device must be installed on septic. |
File(s): |
|
Admin Checklist
Date application was complete: | 10/20/2022 |
Review started by: | Shannon Wiebusch |
Zoning District of project location: | Shoreland |
Required OWHL setback distance: | 100 ft. |
"Other" OHWL setback distance is: | |
Project located in the floodplain? | No |
Base Flood Elevation: | |
Lowest Floor Elevation: | |
Is an after construction elevation certificate required? | |
Property line setbacks appear to be met? | Yes |
Road R-O-W setbacks appear to be met? | Yes |
Bluff setbacks appear to be met? | N/A |
Septic Tank setback appears to be met with/without an engineer's report? | Yes |
Septic Drainfield setback appears to be met with/without an engineer's report? | Yes |
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? | Yes |
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot? | |
Is this After-The-Fact? | No |
Inspector Checklist
Zoning Inspector: | Connor Plagge |
Attach necessary inspection forms/photos: |
|
Notes: | Appears to meet setbacks. Might change the location of drainfield to alternate site. |
Was an onsite conducted for this application? | Yes |