Land Use Application Permit # 2022-8305, App. # App-2022-009474, UID # 206254
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
B-Dirt Construction
Phone:
(218820 - 5736
Email Address:
andrew@b-dirt.com
Mailing Address:
4706 WIlderness Ct
Suite 103
BRAINERD MN 56401
Are you the Property Owner? No

Property Owner Contact

Property Owner Email: markkirchhof@charter.net
Property Owner Phone:
(760672 - 2124

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
01-0-01960037368 410TH AVE
AITKIN MN 56431
AITKIN TWPS:13 T:47 R:27KIRCHHOF, MARK & RAMONAKIRCHHOF, MARK & RAMONA
Enter directions to the property (if no property address assigned):
Head south toward 1st St NW, Turn left onto 1st St NW, Turn left onto Minnesota Ave N, Continue straight to stay on Minnesota Ave N, Continue onto 410th Ave for about 1.3 miles, the property will be on the right

Project Checklist

1.) Is the property zoned Shoreland? Yes
3.) Are there any wetlands or lowlands on/near the project site? Yes
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
No
6.) Are you applying to install a new septic system? Yes

Septic Type

Select the type of septic you are applying for:
Residential Operating Permit (Type 3, 4, 5)

Design Information

Attach Septic Design & Management Plan:
Septic Designer:
None

Operating Permit

Attach the Operating Permit Application & Operating Permit Maintenance Contract:

Pumping Agreement

Installer

Self Install or Licensed Install: Licensed Septic Installer
Licensed Installer Name:
None
Installer License # : 1792
If you selected Self Install please attach the signed Indemnification Form:

Project Description

Please describe your proposed project:
To build new 3 bedroom home ( 46 x 56) with an attached garage (34 x 24).
Pole building on site plan is not proposed right now.
What is the height of your structure? 21 Feet

Project Type

Item 1 - Structure Type: New Residence incl. attached decks/porches/garages
Item 1 - Size: 3641 ft2

Shoreland Data

Setback distance from Ordinary High Water Level to the proposed construction? (closest point) 2585 Feet
Will the proposed structure(s) be less than 35 foot maximum height? Yes
Are you constructing a walkout basement? No
If you are building an accessory structure, will there will be a loft or second story? No

Natural Landscape Protection Plan

Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? No
How many cubic yards of fill or excavation will be done on the property? 830 CuYd
How close to the property line will any fill be placed or any excavation be done? 300 Feet
What percent slope of the land currently exists on the project site? 1 % slope
Select the erosion control methods that will be used throughout and after your project:
(Check all that apply)
6.) What will be done after construction to control
erosion?
Lawn

Site Plan

Attach Site Plan:
Is the site staked and ready for inspection? Yes

Additional Info

Additional info:
(optional)
Fill for the house
330 yards for the inside of the structure
380 yards for the perimeter (outside) of the structure

The driveway already is above the section 5 of the floodplain ordinance.  We will be bringing in about 120 yards of class five for the driveway base.
Attachments: (e.g. blueprints, floor plan, compliance inspection, or other information)

Terms

Land Use/Septic Terms & Conditions
  • All appropriate permit fees must be paid in full prior to any necessary review(s) of application.

  • It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.

  • The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.

  • Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).

  • All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.

  • Permit fees are non-refundable after a permit has been approved.

  • The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.

  • Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."

  • Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.

  • Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.

  • Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.

  • I acknowledge that by submitting this application, the application and its attachments are public information.

Invoice #56077 (09/06/2022)

Charge Cost Quantity Total
Non-Taxable
added 09/06/2022 9:35 AM

$550 Flat Fee

$550.00 x 1 $550.00
added 09/06/2022 9:35 AM

$150 Flat Fee

$150.00 x 1 $150.00
added 09/06/2022 9:35 AM

$400 Flat Fee

$400.00 x 1 $400.00
Grand Total
Total $1,100.00
Payment 09/06/2022$800.00
Payment 09/13/2022$300.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantAndrew RANWEILER - 09/26/2022 10:04 AM
90a80945db4ca37bbb0213c23785e990
ac2004ce84a3bf13a76678f535889b5f
 
#1 Adminstrative Approval GroupShannon Wiebusch - 09/26/2022 8:14 AM
99e2e5f787038f968c6146574f9ac326
8386b9e042d814e3bebb624f0e9de2d8
 
#2 Inspector GroupHenry Egland - 09/29/2022 11:26 AM
24fff706afda7c222c5ea261a151c003
a7e78fdf44d53b5e2ef93c0e5f20683f
 
#3 Level Three Final ActionKim Burton - 09/29/2022 3:05 PM
151b61a759ba28c6888ddfa036aaa261
d91c079fd1f236914623227f8062367a
 
Application has been approved. All signatures have been obtained.
Text:
Permit # 47340. Approved for 3641 sq/ft residence and 3 bdrm Type II mound septic with operating permit #803
(Type III mound in floodplain)
condition of permit: Must provide a post-construction elevation certificate. Must comply with section 5 of the Floodplain Management Ordinance.



Paid twice on the dwelling Refund to be issued. KB
Paid $700 on 9/13/22 (only $300 was due). $400 refunded 9/21/22 KB
File(s):
Text:
File(s):
    Date application was complete: 09/22/2022
    Review started by: Shannon Wiebusch
    Zoning District of project location: Shoreland
    Required OWHL setback distance:
    "Other" OHWL setback distance is: shoreland because in the extent of the floodplain.
    Project located in the floodplain? Yes
    Base Flood Elevation:
    Lowest Floor Elevation:
    Is an after construction elevation certificate required? Yes
    Property line setbacks appear to be met? Yes
    Road R-O-W setbacks appear to be met? Yes
    Bluff setbacks appear to be met? N/A
    Septic Tank setback appears to be met with/without an engineer's report? Yes
    Septic Drainfield setback appears to be met with/without an engineer's report? Yes
    Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
    Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot?
    Is this After-The-Fact? No
    Zoning Inspector: Kevin Turnock
    SSTS Type: Type III
    SSTS Design: "Other"/Performance System (III, IV, V)
    New or Replacement SSTS: New SSTS
    GPD: 1-2,499 gpd
    # of bedrooms: 3
    Does this system require an Operating Permit? Yes
    Operating Permit #: 803
    Does this system belong to an other establishment? No
    Is this a Cluster System? No
    Attachments:
      Zoning Inspector: Henry Egland
      Attach necessary inspection forms/photos:
      Notes:
      All setbacks were met.
      Was an onsite conducted for this application? Yes
      Self Install?
      Installer Name:
      NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
      Borden Excavating IncL179201/10/2025218-765-3397 13110 Borden Rd, Merrifield MN 56465YesYesNoNo
      New Tanks: 1
      Existing Tanks: 0
      Date of Final Inspection: 08/17/2023
      Attach Final Certificate of Installation:
      Low Interest Loan or SSTS Grant project? No