Land Use Application Permit # 2022-7910, App. # App-2022-008679, UID # 204579
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
Sue and Dennis Daniello
Phone:
(720934 - 9601
Email Address:
suziedaniello@aol.com
Mailing Address:
5237 Black Squirrel Run
Roxborough CO 80125
Are you the Property Owner? Yes

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
07-0-03790045745 Townline Lake Rd
AITKIN, MN 56431
FARM ISLAND TWPS:19 T:46 R:27RDTOWNLINE LAKE (FI)DANIELLO, DENNIS & SUE TRUST (2/3)DANIELLO, DENNIS & SUE TRUST (2/3)
Enter directions to the property (if no property address assigned):
210 West to County Rd 28, South on County Rd 28 to 310th.  Turn right on 310th (the Doris Cemetery and Cedar Lake Norwegian Lutheran Church is on the left).  310th becomes Town Line Lake Road.  Our address is 45745 Town Line Lake Road.  Straight ahead down our driveway. ( Do not make a left at the bottom of the drive)

Project Checklist

1.) Is the property zoned Shoreland? Yes
3.) Are there any wetlands or lowlands on/near the project site? No
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
Yes
6.) Are you applying to install a new septic system? Yes

Existing Septic Status

Do you have a Certificate of Compliance, Certificate of Installation, Design for a new system, or does your project fall under Exemption A or B above? Yes

Septic Type

Select the type of septic you are applying for:
Residential Mound (Type 1)

Design Information

Attach Septic Design & Management Plan:
Septic Designer:
None

Installer

Self Install or Licensed Install: Licensed Septic Installer
Licensed Installer Name:
None
Installer License # : 747

Project Description

Please describe your proposed project:
We are proposing to add a three season 16' X 16'  porch on the south end of our cabin.
What is the height of your structure? 12 Feet

Project Type

Item 1 - Structure Type: Residence Addition
Item 1 - Size: 256 ft2

Shoreland Data

Setback distance from Ordinary High Water Level to the proposed construction? (closest point) 130 Feet
Will the proposed structure(s) be less than 35 foot maximum height? Yes
Are you constructing a walkout basement? No

Natural Landscape Protection Plan

Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? No
How many cubic yards of fill or excavation will be done on the property? 0 CuYd
How close to the property line will any fill be placed or any excavation be done? 250 Feet
What percent slope of the land currently exists on the project site? 0 % slope
Select the erosion control methods that will be used throughout and after your project:
(Check all that apply)
6.) What will be done after construction to control
erosion?
Will not be necessary, since it will not change the current conditions.

Site Plan

Attach Site Plan:
Is the site staked and ready for inspection? Yes

Terms

Land Use/Septic Terms & Conditions
  • All appropriate permit fees must be paid in full prior to any necessary review(s) of application.

  • It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.

  • The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.

  • Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).

  • All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.

  • Permit fees are non-refundable after a permit has been approved.

  • The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.

  • Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."

  • Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.

  • Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.

  • Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.

  • I acknowledge that by submitting this application, the application and its attachments are public information.

Invoice #54407 (04/15/2022)

Charge Cost Quantity Total
Non-Taxable
added 01/12/2022 3:27 PM

$300 Flat Fee

$300.00 x 1 $300.00
added 01/12/2022 3:27 PM

$350 Flat Fee

$350.00 x 1 $350.00
Grand Total
Total $650.00
Payment 04/15/2022$650.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
Applicantonline submittal - 04/15/2022 11:48 AM - witnessed by Kim Burton
b0223b431bd2faeb90f0e15165e024a3
73bbe4d2d9a25d78745d50e3ee3c4138
 
#1 Adminstrative Approval GroupHenry Egland - 04/18/2022 10:20 AM
52ecb5fe32241f600169bfd83b18e6d1
ca538954dbe4d43dc2a324b719325faf
 
#2 Inspector GroupHenry Egland - 05/16/2022 8:58 AM
c8a4e8fff7724b26dbf11903b9927db9
09f6efc272429693de646d179199163f
 
#3 Level Three Final ActionMolly Oestreich - 05/17/2022 8:31 AM
86482e06d20fe86587de3cc0864e3af6
4def780008d6d9f53cc53d2e56e348fb
 
Application has been approved. All signatures have been obtained.
Text:
Permit #46882. Approved for 16'x16' residence addition - one-time 50% volume expansion and a 3 bdrm Type I mound septic.

Amended from 16'x16' to 18'x20' on 5/26/22 - H.E.
File(s):
Text:
Email from Becky attached below. KB
File(s):
Date application was complete: 04/15/2022
Review started by: Henry Egland
Zoning District of project location: Shoreland
Required OWHL setback distance: 150 ft.
"Other" OHWL setback distance is:
Project located in the floodplain? No
Base Flood Elevation:
Lowest Floor Elevation:
Is an after construction elevation certificate required?
Property line setbacks appear to be met? Yes
Road R-O-W setbacks appear to be met? Yes
Bluff setbacks appear to be met? N/A
Septic Tank setback appears to be met with/without an engineer's report? Yes
Septic Drainfield setback appears to be met with/without an engineer's report? Yes
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot?
Is this After-The-Fact? No
Zoning Inspector: Kevin Turnock
SSTS Type: Type I
SSTS Design: Mound (Type I)
New or Replacement SSTS: Replacement SSTS
GPD: 1-2,499 gpd
# of bedrooms: 3
Does this system require an Operating Permit? No
Operating Permit #:
Does this system belong to an other establishment? No
Is this a Cluster System? No
Attachments:
    Zoning Inspector: Henry Egland
    Attach necessary inspection forms/photos:
    Notes:
    Using one-time 50% volume expansion
    Was an onsite conducted for this application? Yes
    Self Install? No
    Installer Name:
    NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
    Schrupp Excavating LLCL74704/17/2026218-587-4038 3003 36th St SW, Pine River MN 56474NoYesNoNo
    New Tanks: 1
    Existing Tanks: 0
    Date of Final Inspection: 08/26/2023
    Attach Final Certificate of Installation:
    Low Interest Loan or SSTS Grant project?
    Powered by