Land Use Application Permit # 2024-0609, App. # 2024-001586, UID # 211852
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
Beau Munsell
Phone:
(320587 - 4990
Email Address:
beau@excelsiorhomesinc.com
Mailing Address:
1355 Highway 7 West
Hutchinson MN 55350
Are you the Property Owner? No

Property Owner Contact

Property Owner Email: aleesha_06@hotmail.com
Property Owner Phone:
(763498 - 9666

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
12-0-04180334177 670TH ST
HILL CITY MN 55748
HILL LAKE TWPS:24 T:52 R:26SAUL, MATTHEW & ALEESHASAUL, MATTHEW & ALEESHA

Project Checklist

1.) Is the property zoned Shoreland? No
2.) Is the property located in a flood zone? No
3.) Are there any wetlands or lowlands on/near the project site? Yes
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
No
6.) Are you applying to install a new septic system? Yes

Septic Type

Select the type of septic you are applying for:
Residential Mound (Type 1)

Design Information

Attach Septic Design & Management Plan:
Septic Designer:
NameLicense #ExpirationPhoneAddressDesigner
Ron Ex ExcavatingL69706/21/2025218-327-9273 32731 Woodland Pk. Rd, Grand Rapids MN 55744Yes

Installer

Self Install or Licensed Install: Licensed Septic Installer
Licensed Installer Name:
NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
KLS Excavating LLCL437604/17/2025218-360-229442769 County Road 162, Deer River MN 56636NoYesNoNo

Project Description

Please describe your proposed project:
Install new 2 BR / 2BA -  26.66' x 48' manufactured home on frost pier foundation.  Install new mound system and deep well

Project Type

Item 1 - Structure Type: New Residence incl. attached decks/porches/garages
Item 1 - Type of Construction: Steel beam
Item 1 - Size: 1280 ft2

Site Plan

Please include all applicable items from the checklist on your site plan. See example site plan below:
All Existing Structures & Dimensions
All Proposed Structures & Dimensions
Location of Driveways & Access Roads
Location of Well(s)
Location of Septic System(s)
Distance of Proposed Structures to OHWL (closest point)
Distance of Proposed Structures to Septic System(s)
Distance of Proposed Structures to Property Lines
Distance of Proposed Structures to Road Right-of-Way
Distance of Proposed Structures to Alley or Boulevard
Distance of Proposed Structure to Top of Bluff
Attach Site Plan:
Is the site staked and ready for inspection? No

Additional Info

Additional info:
(optional)
Just a note in regards to site plan and staking...there are 2 stakes for rear (east) side of home but home site is not completely squared & staked

Terms

Land Use/Septic Terms & Conditions
  • All appropriate permit fees must be paid in full prior to review of the application.
    Permit fees are non-refundable after a permit is approved.

  • It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.

  • The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.

  • Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).

  • All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
    Property lines need to be clearly marked or staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
    Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.

  • After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.

  • The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.

  • Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."

  • Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.

  • Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.

  • I acknowledge that by submitting this application, the application and its attachments are public information.

Invoice #61078 (07/16/2024)

Charge Cost Quantity Total
Non-Taxable
added 07/16/2024 2:37 PM

$400 Flat Fee

$400.00 x 1 $400.00
added 07/16/2024 2:37 PM

$350 Flat Fee

$350.00 x 1 $350.00
Grand Total
Total $750.00
Payment 07/16/2024$750.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
Applicantonline submittal - 07/19/2024 1:58 PM - witnessed by Kim Burton
22021acd4898f76d2053758d2bfc37ba
a9e72c2b49faf7c07a0190467294d1b4
 
#1 Administrative ReviewConnor Plagge - 07/22/2024 12:42 PM
0300d01518efdb03a904851f20b19886
0a6e571801da450e85d40fb3a337457d
 
#2 Inspector ReviewJody Grund - 07/24/2024 4:30 PM
c6c68a7109458c45870de2ccdbe5d038
61033ce8f5413dff1cf88347496d4329
 
#3 Final ApprovalConnor Plagge - 07/25/2024 2:28 PM
da218ded4121c237d1249ba3905f8b61
0bd825e0472b6bfdf40880fac1d4d57b
 
Application has been approved. All signatures have been obtained.
Text:
Permit #48886

Approved for a 1280 sq ft Residence and a 2 bdrm Type I Mound Septic.
File(s):
Text:
File(s):
    Date application was complete: 07/19/2024
    Review started by: Connor Plagge
    Zoning District of project location: Farm Residential
    Required OWHL setback distance:
    "Other" OHWL setback distance is:
    Project located in the floodplain? No
    Base Flood Elevation:
    Lowest Floor Elevation:
    Is an after construction elevation certificate required?
    Property line setbacks appear to be met? Yes
    Road R-O-W setbacks appear to be met? Yes
    Bluff setbacks appear to be met? N/A
    Septic Tank setback appears to be met with/without an engineer's report? Yes
    Septic Drainfield setback appears to be met with/without an engineer's report? Yes
    Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
    Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot? New Construction
    Is this After-The-Fact? No
    Zoning Inspector: Connor Plagge
    SSTS Type: Type I
    SSTS Design: Mound (Type I)
    New or Replacement SSTS: New SSTS
    GPD: 1-2,499 gpd
    # of bedrooms: 2
    Does this system require an Operating Permit? No
    Operating Permit #:
    Does this system belong to an other establishment? No
    Is this a Cluster System? No
    Attachments:
      Zoning Inspector: Jody Grund
      Attach necessary inspection forms/photos:
      Notes:
      Approved to Install new 2 BR / 2BA -  26.66' x 48' manufactured home.  Setbacks appear to be met.
      Was an onsite conducted for this application? Yes
      Self Install?
      Installer Name:
      None
      New Tanks:
      Existing Tanks:
      Date of Final Inspection:
      Attach Final Certificate of Installation:
        Low Interest Loan or SSTS Grant project?
        Powered by