SSTS Operating Permit Permit # OP 388-2019, App. # App-2024-000993, UID # 210817
Renewal of Permit # OP 388
App. Status: Renewed
Valid: 06/07/2024 - 09/30/2024
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Applicant Information

Are you the property owner? Yes

Facility Information

Renewal Type:
5 Years
Permittee Contact Information (property owner):
Name:
Robert Dotzler
Phone:
(763434 - 4909
Mailing Address:
20920 Hastings St NE
Cedar MN 55011
Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
34-1-07270011683 117th St
FINLAYSON, MN 55735
WAGNER TWPECHO HILL TOWNSITES:26 T:43 R:22RDPINE LAKE (WAGNER TWP)DOTZLER, ROBERT J & DIANE CDOTZLER, ROBERT J & DIANE C
System Type: Type 4
Treatment Level: C
Residential/Commercial: Residential
System Design Flow (gpd): 300
System Description:
Sewage will flow by gravity from the home to a 550 gallon trash trap. Effluent will then flow by gravity to a 450 gallon chamber with a MircoFAST 0.5 pretreatment unit. Effluent will then enter the 650 gallon pump chamber. A timed dose pump will dose effluent to a 12' x 21' Pressure bed built from washed rock or EZ Flow drainfield media. A 0.83 gpd/ft2 soil sizing factor was used to calculate the size for the drainfield. Some of the new pressure bed may be built over the existing drainfield area. If this is the case, the installer shall dig out the existing drainfield and adjacent soils and replace with clean mound sand. Once the bed is installed, the installer is to overfill the area with sandy loam prior to installing 6" of topsoil over the area

Service Provider

Attach Signed Maintenance Contract:
Select your Service Provider/Inspector/Maintainer:
NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
Septic CheckL262402/21/2026320-983-2447 6074 Keystone Rd, Milaca MN 56353YesYesYesYes
Service Provider Email: info@septiccheck.com

Monitoring Requirements

Monitoring Requirements:
ParameterEffluent LimitsFrequencyLocation
*Design Flow (gpd)300 GPDMonthlyFlow Meter
*Ponding/Surfacing in Soil TreatmentMinimal ponding/no surfacingAnnuallyDrainfield
Average Flow (gpd)150 GPDBi-AnnualFlow Meter
CBOD5 (mg/L)15 mg/lAs NeededAfter treatment
TSS (mg/L)15 mg/lAs NeededAfter treatment
Fecal Coliform Bacteria (#/100mL)1,000 cfu/100 mlAnnuallyAfter treatment

Maintenance Requirements

Maintenance Requirements:
System ComponentMaintenanceFrequency
*Septic Tank/Trash TankCheck sludge/scum levels and pump if neededBi-Annually
*Pump Tank and ControlsCheck and calibrate if neededBi-Annually
Advanced Treatment ProductCheck functionalityBi-Annually
*Soil Treatment and DispersalCheck for surfacing/pondingAnnually

Renewal Files

Attach the Flow Readings and Monitoring/Maintenance Report from your Service Provider:

Invoice #60135 (03/29/2024)

Charge Cost Quantity Total
Non-Taxable
added 03/29/2024 10:12 AM

$150.00 x 1 $150.00
Grand Total
Total $150.00
Payment 03/29/2024$150.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantRobert Dotzler - 03/29/2024 10:14 AM - witnessed by Shannon Wiebusch
95f1d0943232f4d58c6c84d8697c1194
1e1cfae4096345a315a0fc34e4e1a0f1
 
#1 Planning & ZoningShannon Wiebusch - 06/07/2024 1:57 PM
a81d92c7c33f3d2c6948a4ead74e248a
4132a2959f2b915a5bdd4a72021181af
 
Application has been approved. All signatures have been obtained.
Public Notes:
6/7/24 mailing address updated.
Attachments:
    Expiration Date: 09/30/2024
    Internal Notes:
    5/30/19 rec'd septic check report dated 5/2/19 Fecal exceeded limit on sampling report. Septic check will re-sample fecal.
    5/8/19 rec'd cotract and check. Renewed ltr sent
    2/2019 rec'd septic check report dated 5/31/18 and 10/2/18
    1/18/18 rec'd monitoring report from Septic Check dated 6/1/17 and 11/9/17
    1-17-17 rec'd monitoring from Septic Check dated 5/10/16
    3.4.16 rec'd monitoring from Septic Check dated 5.22.15
    3.30.15 received monitoring results from Septic Check.
    Attachments: