Land Use Application Permit # 2022-8536, App. # App-2022-009799, UID # 206778
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
Mike Mathison
Phone:
(218820 - 3525
Email Address:
mtmpreferred@gmail.com
Mailing Address:
11874 Forestview Drive
Baxter MN 56425
Are you the Property Owner? No

Property Owner Contact

Property Owner Email: mjsizzy@gmail.com
Property Owner Phone:
(218791 - 6782

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
07-1-12850023666 CEDAR LAKE DR
AITKIN, MN 56431
FARM ISLAND TWPBUTLERS CEDAR SHORESS:6 T:46 R:27RDCEDAR LAKE (AITKIN/FI TWPS)STREIFEL, JOLANDA & ZIMNEY, DAWNSTREIFEL, JOLANDA & ZIMNEY, DAWN
Enter directions to the property (if no property address assigned):
Hwy 210 out of Aitkin towards Deerwood. Go approx. 05 miles turn left on Cedar Lake Drive. Go approx. 01 mile, the property is on the left.

Project Checklist

1.) Is the property zoned Shoreland? Yes
3.) Are there any wetlands or lowlands on/near the project site? No
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
Yes
6.) Are you applying to install a new septic system? No

Existing Septic Status

Do you have a Certificate of Compliance, Certificate of Installation, Design for a new system, or does your project fall under Exemption A or B above? Yes

Project Description

Please describe your proposed project:
There is an existing foundation on the property 40 x 26'. We are adding a 26 x 27.5 attached garage to an existing foundation on the North side. We will be adding a new home on top of the existing foundation and above the new attached garage. The garage is a tuck under garage. Adding L shaped Deck that is 350sq/ft on lake side.
What is the height of your structure? 24 Feet

Project Type

Item 1 - Structure Type: New Residence incl. attached decks/porches/garages
Item 1 - Size: 2108 ft2

Shoreland Data

Setback distance from Ordinary High Water Level to the proposed construction? (closest point) 110 Feet
Will the proposed structure(s) be less than 35 foot maximum height? Yes
Are you constructing a walkout basement? No
If you are building an accessory structure, will there will be a loft or second story? No

Natural Landscape Protection Plan

Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? No
How many cubic yards of fill or excavation will be done on the property? 30 CuYd
How close to the property line will any fill be placed or any excavation be done? 10 Feet
What percent slope of the land currently exists on the project site? 20 % slope
Select the erosion control methods that will be used throughout and after your project:
(Check all that apply)
6.) What will be done after construction to control
erosion?
Landscaping where needed. Sod and grass.

Site Plan

Attach Site Plan:
Is the site staked and ready for inspection? Yes

Terms

Land Use/Septic Terms & Conditions
  • All appropriate permit fees must be paid in full prior to any necessary review(s) of application.

  • It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.

  • The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.

  • Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).

  • All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.

  • Permit fees are non-refundable after a permit has been approved.

  • The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.

  • Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."

  • Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.

  • Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.

  • Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.

  • I acknowledge that by submitting this application, the application and its attachments are public information.

Invoice #56529 (11/22/2022)

Charge Cost Quantity Total
Non-Taxable
added 11/22/2022 8:24 AM

$550 Flat Fee

$550.00 x 1 $550.00
Grand Total
Total $550.00
Payment 11/22/2022$550.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantMike T. Mathison - 11/23/2022 8:15 AM
9b009b6fe11882e92e4afaab52cb65e9
2e3087f7c9a4fd25cc85d916318a9efa
 
#1 Adminstrative Approval GroupConnor Plagge - 11/23/2022 12:16 PM
8f4d82053af96e6e05a595521288c672
e6cbde35f2ec0215ba83c156ee325b5d
 
#2 Inspector GroupConnor Plagge - 11/28/2022 9:23 AM
ff4ee5a0d9587b82542b49e458b19073
881def7325424709f31e7b2d7ad76ac8
 
#3 Level Three Final ActionKim Burton - 11/28/2022 1:51 PM
4e938a848bcde83c045998f02c805ebd
e851e9d8270af6b9217033a14d19ac46
 
Application has been approved. All signatures have been obtained.
Text:
Permit # 47497. Approved for a 2108 sq ft New Residence incl. attached decks/porches/garages with one condition;
1. Must remain a two bedroom residence unless septic system is upgraded.


Applicant also paid $150 for an attached deck. Amount to be refunded. KB
Refund Issued (check ) 12/20/22 KB
File(s):
Text:
File(s):
Date application was complete: 11/23/2022
Review started by: Connor Plagge
Zoning District of project location: Shoreland
Required OWHL setback distance: 100 ft.
"Other" OHWL setback distance is:
Project located in the floodplain? No
Base Flood Elevation:
Lowest Floor Elevation:
Is an after construction elevation certificate required?
Property line setbacks appear to be met? Yes
Road R-O-W setbacks appear to be met? Yes
Bluff setbacks appear to be met? N/A
Septic Tank setback appears to be met with/without an engineer's report? Yes
Septic Drainfield setback appears to be met with/without an engineer's report? Yes
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot?
Is this After-The-Fact? No
Zoning Inspector:
SSTS Type:
SSTS Design:
New or Replacement SSTS:
GPD:
# of bedrooms:
Does this system require an Operating Permit?
Operating Permit #:
Does this system belong to an other establishment?
Is this a Cluster System?
Attachments:
    Zoning Inspector: Connor Plagge
    Attach necessary inspection forms/photos:
    Notes:
    Appears to meet all setbacks.
    Was an onsite conducted for this application? Yes
    Self Install?
    Installer Name:
    None
    New Tanks:
    Existing Tanks:
    Date of Final Inspection:
    Attach Final Certificate of Installation:
      Low Interest Loan or SSTS Grant project?