Enter Applicant Contact Information: |
|
||||||||||||||||||||||||||||||||
Are you the Property Owner? | Yes |
Property Location
Property Location: |
|
Enter directions to the property (if no property address assigned): | Take TH210 East to 400th Ave. Turn right. Proceed toTH 47. Turn left on TH 47. Proceed to Deer St. Turn right . Proceed to Oak Ave ,turn right. Proceed 4.3 miles to property. |
Project Checklist
1.) Is the property zoned Shoreland? | Yes |
3.) Are there any wetlands or lowlands on/near the project site? | Yes |
4.) Will the structure(s) be used for commercial purposes? | No |
5.) Is there an existing septic system on the property? (Outhouse/Privies are also considered septic systems) |
No |
6.) Are you applying to install a new septic system? | Yes |
Septic Type
Select the type of septic you are applying for: | Residential Mound (Type 1) |
Design Information
Attach Septic Design & Management Plan: | |
Septic Designer: |
None
|
Installer
Self Install or Licensed Install: | Licensed Septic Installer |
Licensed Installer Name: |
None
|
Installer License # : | L4071 |
Project Description
Please describe your proposed project: | We are proposing to build a single family home with an attached garage. The living area is 52 feet by 36 feet. It will have a shed roof that will provide 1.5 stories of living space, and a poured concrete basement under the living area. The attached garage is 24 ft wide by 36 ft deep. |
What is the height of your structure? | 19 Feet |
Project Type
Item 1 - Structure Type: | New Residence incl. attached decks/porches/garages |
Item 1 - Size: | 2736 ft2 |
Shoreland Data
Setback distance from Ordinary High Water Level to the proposed construction? (closest point) | 650 Feet |
Will the proposed structure(s) be less than 35 foot maximum height? | Yes |
Are you constructing a walkout basement? | No |
If you are building an accessory structure, will there will be a loft or second story? | No |
Natural Landscape Protection Plan
Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? | No |
How many cubic yards of fill or excavation will be done on the property? | 270 CuYd |
How close to the property line will any fill be placed or any excavation be done? | 60 Feet |
What percent slope of the land currently exists on the project site? | 2 % slope |
Select the erosion control methods that will be used throughout and after your project: (Check all that apply) |
|
6.) What will be done after construction to control erosion? |
Soil excavated from basement will be placed at grade around foundation. Top soil and subsoil will segregated during excavation. Top soil will be used to dress all disturbed areas. Fiber mulch will be spread on all disturbed areas and disked into soil. Grass seed mix including fast growing cover varieties will be applied with mulch. Silt fence left in place until vegetation is established. |
Site Plan
Attach Site Plan: |
|
Is the site staked and ready for inspection? | Yes |
Terms
All appropriate permit fees must be paid in full prior to any necessary review(s) of application.
It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.
The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.
Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).
All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.
Permit fees are non-refundable after a permit has been approved.
The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.
Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."
Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.
Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.
Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.
I acknowledge that by submitting this application, the application and its attachments are public information.
Invoice #55672 (07/26/2022)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 07/26/2022 11:15 AM $550 Flat Fee |
$550.00 | x 1 | $550.00 |
added 07/25/2022 12:58 PM $350 Flat Fee |
$350.00 | x 1 | $350.00 |
Grand Total | |||
Total | $900.00 | ||
Payment 07/29/2022 | $900.00 | ||
Due | $0.00 |
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Connie J. Wetmore - 07/30/2022 5:23 PM 06ab57d028fbde5cf03eac7687177210 d86e15890d318286a8a2e650f2e103d6 | |
#1 Adminstrative Approval Group | Molly Oestreich - 08/01/2022 7:56 AM 61221fbae32bc08a4ddf36cd0e3c1359 03b9a8bc6246cd323a0607670bacac04 | |
#2 Inspector Group | Molly Oestreich - 08/08/2022 9:34 AM 98d62ded1dc48ab318fc54ef2095ad03 f056fbd0531b7114d702da4548422e1f | |
#3 Level Three Final Action | Sarah McMillan - 08/08/2022 9:50 AM a63b733a6858e078c32cf3734048a635 0edc057559ea1a5b977386f82160f591 |
Text: | Permit #47197 Approved for a 2736 sqft residence and a 4 bdrm Type I mound septic Spoke with septic installer regarding extending permit. 90 day extension granted.KT |
File(s): |
|
Text: | |
File(s): |
Date application was complete: | 07/30/2022 |
Review started by: | Molly Oestreich |
Zoning District of project location: | Shoreland |
Required OWHL setback distance: | |
"Other" OHWL setback distance is: | |
Project located in the floodplain? | No |
Base Flood Elevation: | |
Lowest Floor Elevation: | |
Is an after construction elevation certificate required? | |
Property line setbacks appear to be met? | Yes |
Road R-O-W setbacks appear to be met? | Yes |
Bluff setbacks appear to be met? | N/A |
Septic Tank setback appears to be met with/without an engineer's report? | Yes |
Septic Drainfield setback appears to be met with/without an engineer's report? | Yes |
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? | |
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot? | |
Is this After-The-Fact? | No |
Zoning Inspector: | Kevin Turnock |
SSTS Type: | Type I |
SSTS Design: | Mound (Type I) |
New or Replacement SSTS: | New SSTS |
GPD: | 1-2,499 gpd |
# of bedrooms: | 4 |
Does this system require an Operating Permit? | No |
Operating Permit #: | |
Does this system belong to an other establishment? | No |
Is this a Cluster System? | No |
Attachments: |
Zoning Inspector: | Molly Oestreich |
Attach necessary inspection forms/photos: | |
Notes: | Approved for a 2736 sqft residence and a 4 bdrm Type I mound septic |
Was an onsite conducted for this application? | Yes |
Self Install? | |
Installer Name: |
|
New Tanks: | 1 |
Existing Tanks: | 0 |
Date of Final Inspection: | 10/06/2023 |
Attach Final Certificate of Installation: |
|
Low Interest Loan or SSTS Grant project? |