Land Use Application Permit # 2021-7518, App. # App-2021-008172, UID # 204056
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
Andrew Ranweiler
Phone:
(218820 - 5736
Email Address:
andrew@b-dirt.com
Mailing Address:
4706 WIlderness Ct
Suite 103
BRAINERD MN 56401
Are you the Property Owner? No

Property Owner Contact

Property Owner Email: coachchr@hotmail.com
Property Owner Phone:
(612802 - 5930

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
07-1-07950329777 PIONEER AVE
AITKIN MN 56431
FARM ISLAND TWPDUMMERS SUBDIVISION OF LOTS 3 AND 4S:28 T:46 R:27RDFARM ISLAND LAKELIND, CHRISTOPHER & CAROLLIND, CHRISTOPHER & CAROL
Enter directions to the property (if no property address assigned):
Head West on MN-210 W/2nd St NW toward 4th Ave NW (3 miles) Turn Left onto Pioneer Ave (6.2 miles to destination on your right fire #29715)

Project Checklist

1.) Is the property zoned Shoreland? Yes
3.) Are there any wetlands or lowlands on/near the project site? No
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
Yes
6.) Are you applying to install a new septic system? Yes

Existing Septic Status

Do you have a Certificate of Compliance, Certificate of Installation, Design for a new system, or does your project fall under Exemption A or B above? Yes

Septic Type

Select the type of septic you are applying for:
Residential Other/Performance (Type 3)
Residential Operating Permit (Type 3, 4, 5)

Design Information

Attach Septic Design & Management Plan:
Septic Designer:
None

Operating Permit

Attach the Operating Permit Application & Operating Permit Maintenance Contract:

Pumping Agreement

Installer

Self Install or Licensed Install: Licensed Septic Installer
Licensed Installer Name:
None
Installer License # : 1792

Project Description

Please describe your proposed project:
I am proposing to build a 62 x 38 House with an attached 36 x 28 Garage, 7 x 24 front covered deck and a 40 x 10 lakeside deck
What is the height of your structure? 28 Feet

Project Type

Item 1 - Structure Type: New Residence incl. attached decks/porches/garages
Item 1 - Size: 3751 ft2

Shoreland Data

Setback distance from Ordinary High Water Level to the proposed construction? (closest point) 250 Feet
Will the proposed structure(s) be less than 35 foot maximum height? Yes
Are you constructing a walkout basement? Yes

Natural Landscape Protection Plan

Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? No
How many cubic yards of fill or excavation will be done on the property? 648 CuYd
How close to the property line will any fill be placed or any excavation be done? 55 Feet
What percent slope of the land currently exists on the project site? 4 % slope
Select the erosion control methods that will be used throughout and after your project:
(Check all that apply)
6.) What will be done after construction to control
erosion?
Vegetation

Site Plan

Attach Site Plan:
Is the site staked and ready for inspection? Yes

Additional Info

Invoice #53936 (09/28/2021)

Charge Cost Quantity Total
Non-Taxable
added 09/28/2021 2:42 PM

$550 Flat Fee

$550.00 x 1 $550.00
added 09/28/2021 2:42 PM

$150 Flat Fee

$150.00 x 1 $150.00
added 09/28/2021 2:42 PM

$400 Flat Fee

$400.00 x 1 $400.00
Grand Total
Total $1,100.00
Payment 06/22/2021$900.00
Payment 09/27/2021$200.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
Applicant 
App. Status must be Pending Review
Text:
Permit #46589. Approved for a  62 x 38 residence with attached 36 x 28 Garage, 7 x 24 covered deck, 40 x 10 deck and 6 bdrm Type III mound septic with operating permit# 762

(PID # and legal description were corrected on permits on 9/27/22. sw)
File(s):
Text:
File(s):
    Date application was complete: 09/27/2021
    Review started by: Shannon Wiebusch
    Zoning District of project location: Shoreland
    Required OWHL setback distance: 100 ft.
    "Other" OHWL setback distance is:
    Project located in the floodplain? No
    Base Flood Elevation:
    Lowest Floor Elevation:
    Is an after construction elevation certificate required?
    Property line setbacks appear to be met? Yes
    Road R-O-W setbacks appear to be met? Yes
    Bluff setbacks appear to be met?
    Septic Tank setback appears to be met with/without an engineer's report? Yes
    Septic Drainfield setback appears to be met with/without an engineer's report? Yes
    Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
    Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot?
    Is this After-The-Fact? No
    Zoning Inspector: Kevin Turnock
    SSTS Type: Type III
    SSTS Design: "Other"/Performance System (III, IV, V)
    New or Replacement SSTS: Replacement SSTS
    GPD: 1-2,499 gpd
    # of bedrooms: 6
    Does this system require an Operating Permit? Yes
    Operating Permit #: 762
    Does this system belong to an other establishment? No
    Is this a Cluster System? No
    Attachments:
      Zoning Inspector: Bryan Hargrave
      Attach necessary inspection forms/photos:
        Notes:
        Was an onsite conducted for this application? Yes
        Self Install?
        Installer Name:
        None
        New Tanks: 2
        Existing Tanks: 0
        Date of Final Inspection: 08/01/2022
        Attach Final Certificate of Installation:
        Low Interest Loan or SSTS Grant project?