OneGov
App. Status: ApprovedAitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
Contact Information
Enter Applicant Contact Information: |
|
||||||||||||||||||||||||||||||||
Are you the Property Owner? | No |
Property Owner Contact
Property Owner Email: | catjtreb@gmail.com | ||||
Property Owner Phone: |
|
Property Location
Property Location: |
|
Does your property have an E911 address assigned? | No |
Enter directions to the property (if no property address assigned): | Follow US- 169S, south 18 miles to turn right on MN-200 follow 200 west for 3miles to turn left onto Osprey Ave, follow Osprey for 2.9 miles, driveway will be on the right at 46 Deg 57'34.7" North , 93 Deg 39' 58" West. Follow Driveway west to building site on the left. |
Project Checklist
1.) Is the property zoned Shoreland? | Yes |
3.) Are there any wetlands or lowlands on/near the project site? | Yes |
4.) Will the structure(s) be used for commercial purposes? | No |
5.) Is there an existing septic system on the property? (Outhouse/Privies are also considered septic systems) |
No |
6.) Are you applying to install a new septic system? | Yes |
Septic Type
Select the type of septic you are applying for: | Residential Other/Performance (Type 3) Residential Operating Permit (Type 3, 4, 5) |
Design Information
Attach Septic Design & Management Plan: |
Project Description
Please describe your proposed project: | New Residential Structure including 38' x 48' home with attached 24'x26' garage. Home is to have four bedrooms with a walkout basement. Walls are 8' with 5/12 roof pitches leaving the maximum height to be less than 24'. Deck is to be 12'x28', approximately half of this deck to be enclosed and half open. Foundation to be ICF and structure to be conventional 2x6" framing. |
What is the height of your structure? | 24 Feet |
Project Type
Item 1 - Structure Type: | New Residence incl. attached decks/porches/garages |
Item 1 - Size: | 2160 ft2 |
Select a Septic Item (if applicable): | Residential Other/Performance (Type 3) Residential Operating Permit (Type 3, 4, 5) |
Shoreland Data
Setback distance from Ordinary High Water Level to the proposed construction? (closest point) | 300 Feet |
Will the proposed structure(s) be less than 35 foot maximum height? | Yes |
Are you constructing a walkout basement? | Yes |
Natural Landscape Protection Plan
Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? | No |
How many cubic yards of fill or excavation will be done on the property? | 150 CuYd |
How close to the property line will any fill be placed or any excavation be done? | 200 Feet |
What percent slope of the land currently exists on the project site? | 15 % slope |
Select the erosion control methods that will be used throughout and after your project: (Check all that apply) |
|
6.) What will be done after construction to control erosion? |
Seeded with grass similar to existing condition. |
Site Plan
Attach Site Plan: |
|
Is the site staked and ready for inspection? | Yes |
Additional Info
Additional info: (optional) |
I have attached a county satellite photo for driveway directions to the bldg site. Jim Andrews 218-244-2595 erosion control plan attached |
Attachments: (e.g. blueprints, floor plan, compliance inspection, or other information) |
|
Terms
Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.
It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.
The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.
Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).
All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.
The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.
Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."
Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.
Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.
Invoice #47402 (04/12/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 05/04/2019 7:57 PM $550 Flat Fee |
$550.00 | x 1 | $550.00 |
added 05/08/2019 9:06 AM $150 Flat Fee |
$100.00 | x 1 | $100.00 |
added 05/08/2019 9:06 AM $400 Flat Fee |
$350.00 | x 1 | $350.00 |
Grand Total | |||
Total | $1,000.00 | ||
Payment 05/04/2019 | $850.00 | ||
Payment 05/09/2019 | $150.00 | ||
Due | $0.00 |
Approvals
Approval | Signature |
---|---|
Applicant | James b. Andrews - 05/16/2019 11:11 AM - witnessed by Shannon Wiebusch 8acaf6e43dcbc75735158e77a0d89285 e7267529940f14e3ea9fccd644c74f87 |
#1 Adminstrative Approval Group | Shannon Westerlund - 05/16/2019 11:12 AM ab9c40de3ddb4836d627d1b96acefb88 9b833ae68a619c4771944c7073142608 |
#2 Inspector Group | Bryan Hargrave - 06/02/2019 5:32 PM 8346928d3b221b7859695434cf27d244 d6880c988afe85195505b96554599bef |
#3 Level Three Final Action | Jan Yearneau - 06/03/2019 10:20 AM 84f40125c916d24e29cb94180838298b 170b999893da4d65852c4439b2373f13 |
Public Notes
Text: | Permit# 44301. Approved for a 2160 sq ft new residence and a type III "other" septic system with operating permit #619. |
File(s): |
|
Admin Checklist
Date application was complete: | 05/16/2019 |
Review started by: | Shannon Wiebusch |
Zoning District of project location: | Shoreland |
Required OWHL setback distance: | 100 ft. |
"Other" OHWL setback distance is: | |
Project located in the floodplain? | No |
Base Flood Elevation: | not in fp based on GIS contours |
Lowest Floor Elevation: | |
Is an after construction elevation certificate required? | |
Property line setbacks appear to be met? | Yes |
Road R-O-W setbacks appear to be met? | Yes |
Bluff setbacks appear to be met? | N/A |
Septic Tank setback appears to be met with/without an engineer's report? | Yes |
Septic Drainfield setback appears to be met with/without an engineer's report? | Yes |
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? | Yes |
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot? | |
Is this After-The-Fact? | No |
Inspector Checklist
Zoning Inspector: | Bryan Hargrave |
Attach necessary inspection forms/photos: |
|
Notes: | |
Was an onsite conducted for this application? | Yes |