OneGov
Land Use Application Permit # 2024-0865, App. # 2024-001949, UID # 211581
App. Status: ApprovedAitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
App. Status: ApprovedAitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
Contact Information
Enter Applicant Contact Information: |
|
||||||||||||||||||||||||||||||||
Are you the Property Owner? | Yes |
Property Location
Property Location: |
|
Enter directions to the property (if no property address assigned): | From Aitkin - South on Hwy 47 to Malmo - 1 mile south of Malmo on Hwy 476 to 206th Ave - left at T - house on right |
Project Checklist
1.) Is the property zoned Shoreland? | Yes |
3.) Are there any wetlands or lowlands on/near the project site? | No |
4.) Will the structure(s) be used for commercial purposes? | No |
5.) Is there an existing septic system on the property? (Outhouse/Privies are also considered septic systems) |
Yes |
6.) Are you applying to install a new septic system? | No |
Existing Septic Status
Do you have a Certificate of Compliance, Certificate of Installation, Design for a new system, or does your project fall under Exemption A or B above? | Yes |
Project Description
Please describe your proposed project: | 14x26 Lean-to |
Project Type
Item 1 - Structure Type: | Accessory Building |
Item 1 - Type of Construction: | Wood/Frame |
Item 1 - Size: | 364 ft2 |
Shoreland Data
Setback distance from Ordinary High Water Level to the proposed construction? (closest point) | 200 Feet |
Will the proposed structure(s) be less than 35 foot maximum height? | Yes |
Are you constructing a walkout basement? | Yes |
Natural Landscape Protection Plan
Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? | No |
How many cubic yards of fill or excavation will be done on the property? | 0 CuYd |
How close to the property line will any fill be placed or any excavation be done? | 10 Feet |
What percent slope of the land currently exists on the project site? | 0 % slope |
Select the erosion control methods that will be used throughout and after your project: (Check all that apply) |
Other (explain below) |
Site Plan
Attach Site Plan: |
|
Is the site staked and ready for inspection? | Yes |
Invoice #60829 (06/13/2024)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 09/30/2024 2:59 PM $200 Flat Fee |
$200.00 | x 1 | $200.00 |
Grand Total | |||
Total | $200.00 | ||
Payment 09/30/2024 | $200.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Dennise Joanne Sonnee - 09/30/2024 3:01 PM - witnessed by Connor Plagge 543fcae34c9854a811d1e9ad72b96b4d b676b2bc775449db32e9e939a6ca9b00 | |
#1 Administrative Review | Connor Plagge - 10/01/2024 9:13 AM 3ccebea59e9887bb7cd1f45a84305f28 edda19729fd3b12281626395785b84bd | |
#2 Inspector Review | Connor Plagge - 10/01/2024 3:06 PM afa0d7380331052cd8eeb26a0eabb898 da311a6a56bcd12d9763537965a38325 | |
#3 Final Approval | Connor Plagge - 10/02/2024 9:59 AM d1e018631391b74061216c0d432dab5f 92ae64d7f0667e3eed5b03dcc9224d8c |
Application has been approved. All signatures have been obtained.
Text: | Permit 49082 Approved for a 364 sq ft Accessory Building (14'x26' Lean-to Addition to Garage) |
File(s): |
|
Text: | |
File(s): |
Date application was complete: | 09/30/2024 |
Review started by: | Connor Plagge |
Zoning District of project location: | Shoreland |
Required OWHL setback distance: | 75 ft. |
"Other" OHWL setback distance is: | |
Project located in the floodplain? | No |
Base Flood Elevation: | |
Lowest Floor Elevation: | |
Is an after construction elevation certificate required? | |
Property line setbacks appear to be met? | Yes |
Road R-O-W setbacks appear to be met? | Yes |
Bluff setbacks appear to be met? | N/A |
Septic Tank setback appears to be met with/without an engineer's report? | Yes |
Septic Drainfield setback appears to be met with/without an engineer's report? | Yes |
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? | Yes |
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot? | Redevelopment |
Is this After-The-Fact? | No |
Zoning Inspector: | |
SSTS Type: | |
SSTS Design: | |
New or Replacement SSTS: | |
GPD: | |
# of bedrooms: | |
Does this system require an Operating Permit? | |
Operating Permit #: | |
Does this system belong to an other establishment? | |
Is this a Cluster System? | |
Attachments: |
Zoning Inspector: | Connor Plagge |
Attach necessary inspection forms/photos: |
|
Notes: | |
Was an onsite conducted for this application? | Yes |
Self Install? | |
Installer Name: |
None
|
New Tanks: | |
Existing Tanks: | |
Date of Final Inspection: | |
Attach Final Certificate of Installation: | |
Low Interest Loan or SSTS Grant project? |