SSTS Operating Permit Permit # OP 117, App. # App-2024-000382, UID # 209997
App. Status: Renewed
Valid: 02/09/2024 - 05/31/2019
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Applicant Information

Are you the property owner? Yes

Facility Information

Permit Type:
Initial Application
Permittee Contact Information (property owner):
Name:
Vigstol Family Cabin LLC c/o Richard Vigstol
Phone:
(612201 - 4146
Email Address:
dvusvigstol@frontiernet.net
Mailing Address:
49610 State Hwy 65
McGregor MN 55760
Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
29-0-03510049610 STATE HWY 65
MCGREGOR, MN 55760
SHAMROCK TWPS:18 T:49 R:23GDBIG SANDY LAKEVIGSTOL FAMILY CABIN LLCVIGSTOL FAMILY CABIN LLC
System Type: Type 4
Treatment Level: A
Residential/Commercial: Residential
System Design Flow (gpd): 450 gpd
System Description:
This ISTS will gravity from the proposed house into a new 1960 combination tank.  From there the liquids are pumped into a 12X30 OSI Sand filter.  AN OSI pump vault placed in the sand filter will pump the treated liquids. Treated liquids will be dosed at a maximum of 375 gpd, into a downsized 2.5 bedroom 1-foot sandbase mound with a 10X32 rockbed.

Service Provider

Attach Signed Maintenance Contract:
Select your Service Provider/Inspector/Maintainer:
NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
Ron Ex ExcavatingL69706/21/2024218-327-9273 32731 Woodland Pk. Rd, Grand Rapids MN 55744YesYesYesYes
Service Provider Email: ronald.myers@mchsi.com

Monitoring Requirements

Monitoring Requirements:
ParameterEffluent LimitsFrequencyLocation
*Design Flow (gpd)450 gpdMonthlyWater Meter
*Ponding/Surfacing in Soil TreatmentNoneAnnuallyDispersal System
Monitoring Requirements Comments:
Separation distance compliance limit is 1 foot.

Maintenance Requirements

Maintenance Requirements:
System ComponentMaintenanceFrequency
*Septic Tank/Trash TankSludge & Scum LevelAnnually
*Pump Tank and ControlsComponents and settingsAnnually
Advanced Treatment ProductPressurization of laterals in Sand FilterAnnually
*Soil Treatment and DispersalCheck for surface discharge and acceptance of effluent into groundAnnually
*Soil Treatment and DispersalOverall visual of entire system for landscaping, drainage and cover.Annually

Invoice #59477 (02/09/2024)

Charge Cost Quantity Total
Non-Taxable
added 02/09/2024 11:56 AM

$150.00 x 1 $150.00
Grand Total
Total $150.00
Payment 02/09/2024$150.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantVigstol Family Cabin LLC c/o Richard Vigstol - 02/09/2024 12:28 PM - witnessed by Shannon Wiebusch
84dce3a097af926fe467c9232901f80e
d55f3f7bc12ea39e2eb05fdc536ea87a
 
#1 Planning & ZoningShannon Wiebusch - 02/09/2024 12:29 PM
17c9227386bb1189624c4faaaa2f7826
a944ba6c6f4689da8b0beba59ecbbdb9
 
Application has been approved. All signatures have been obtained.
Public Notes:
Attachments:
    Expiration Date: 05/31/2019
    Internal Notes:
    5/29/19 rec'd payment. Renewed ltr sent
    5/22/19 rec'd signed contract, CI, and readings from Ron Myers. 
    5/13/19 Mark Ritter called for septic info
    5/9/19 Ron Myers emailed for septic info
    5.28.14 sent renewed letter.
    4.15.14 sent renewal information. 4.11.14 gave a copy to Mike O'Keeffe.
    Do not send mail to 1945 130th Ave, Mora, 55051- this is an LLC under his kid's. Mail should be send to Michael at the property address. Sw 4/18/22
    Next renewal 2014
    Letter sent 6/26/09
    Last update in 2007
    Renewed to every 5 years, 08/24/2009.
    Attachments: