SSTS Operating Permit Permit # OP 89, App. # App-2024-000347, UID # 209938
App. Status: Approved
Valid: 02/06/2024 - 05/31/2019
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Applicant Information

Are you the property owner? Yes

Facility Information

Permit Type:
Initial Application
Permittee Contact Information (property owner):
Name:
Lloyd & Lois Welsh
Phone:
(000000 - 0000
Email Address:
cfcolsch@gmail.com
Mailing Address:
51141 207th Pl
McGregor MN 55760
Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
29-1-49010051141 207th Pl
MCGREGOR, MN 55760
SHAMROCK TWPDOUBLE S ACRES SECOND ADDITIONS:5 T:49 R:23GDBIG SANDY LAKECOLSCH, CHAD F & RENEE ACOLSCH, CHAD F & RENEE A
System Type: Type 4
Treatment Level: A
Residential/Commercial: Residential
System Design Flow (gpd): 300 gpd
System Description:
This ISTS is to gravity from the dwelling into the existing 1200 gallon concrete septic tank.  From there the liquids will gravity into a new 1860 precast septic/lift tank.  An OSI AdvanTex AX-10 Series, Mode 1b Textile Filter is to be placed on top of the 1860 septic/lift tank.  Wastewater will percolate through the Textile Filter which will recirculate through the tank and the filter treating the liquids.  The treated liquids will then be pumped into a 10' x 38' Pressure Bed with 18 inches of separation.  The Pressure Bed is to be constructed on "clean sand" with 6 foot dikes at a 3:1 slope.

Service Provider

Attach Signed Maintenance Contract:
Select your Service Provider/Inspector/Maintainer:
NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
Septic CheckL262402/21/2026320-983-2447 6074 Keystone Rd, Milaca MN 56353YesYesYesYes
Service Provider Email: info@septiccheck.com

Monitoring Requirements

Monitoring Requirements:
ParameterEffluent LimitsFrequencyLocation
*Design Flow (gpd)300 gpdMonthlyWater Meter
*Ponding/Surfacing in Soil TreatmentNoneAnnuallyDrainfield
CBOD5 (mg/L)15/220As NeededFiltrate Splitter Valve
TSS (mg/L)15/65As NeededFiltrate Splitter Valve
FO&G (mg/L)30As NeededFiltrate Splitter Valve
Fecal Coliform Bacteria (#/100mL)1,000AnnuallyFiltrate Splitter Valve
Monitoring Requirements Comments:
Separation compliance limit at drainfield is 18 inches.

Maintenance Requirements

Maintenance Requirements:
System ComponentMaintenanceFrequency
*Septic Tank/Trash TankSludge & Scum levelAnnually
*Pump Tank and ControlsCheck operationsAnnually
Advanced Treatment ProductCheck functions of AdvanTex AX FilterAnnually
*Soil Treatment and DispersalAcceptance of effluent into ground and separation distance.Annually
*Soil Treatment and DispersalOverall visual of entire system for landscaping, drainage, coverAnnually

Invoice #59418 (02/06/2024)

Charge Cost Quantity Total
Non-Taxable
added 02/06/2024 9:38 AM

$150.00 x 1 $150.00
Grand Total
Total $150.00
Payment 03/28/2024$150.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantLloyd & Lois Welsh - 02/06/2024 9:39 AM - witnessed by Shannon Wiebusch
aec8e039623e6759a9bd691616bbf8a3
6add114d24fce3db31803f2476728a5d
 
#1 Planning & ZoningShannon Wiebusch - 02/06/2024 9:40 AM
fa75e3e0ffe649a207ec1ca91d1e9f39
94f7bb36a3a7c90bf9deea8f48cb9399
 
Application has been approved. All signatures have been obtained.
Public Notes:
Attachments:
    Expiration Date: 05/31/2019
    Internal Notes:
    Attachments:
      Powered by