SSTS Operating Permit Permit # OP 321, App. # App-2024-000301, UID # 209892
App. Status: Approved
Valid: 07/01/2011 - 09/30/2022
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Facility Information

Permit Type:
Initial Application
Permittee Contact Information (property owner):
Name:
David & Nancy Claussen
Phone:
(218426 - 4436
Mailing Address:
21868 506th Lane
McGregor MN 55760
Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
29-0-01372321868 506th Ln
MCGREGOR, MN 55760
SHAMROCK TWPS:7 T:49 R:23GDBIG SANDY LAKECLAUSSEN, DAVID F & NANCY LCLAUSSEN, DAVID F & NANCY L
System Type: Type 4
Treatment Level: C
Residential/Commercial: Residential
System Design Flow (gpd): 300
System Description:
Puraflo peat filter septic treatment for use with 10x25 existing pressure bed for a two bedroom.  The soils at the existing pressure bed site show slight mottles at 21".  The peat pods will add needed separation to existing bed to pass compliance. The tank is to be replaced with a 1,860 gal precast combo tank. Two Bord na Mona puraflow peat pods are to be installed and an additional 500 gallon pump chamber to supply the existing bed. There is to be a Zable A-300 filter installed and existing bed laterals are to have flush valves added at the ends.

Service Provider

Attach Signed Maintenance Contract:
Select your Service Provider/Inspector/Maintainer:
NameLicense #ExpirationPhoneAddressInspectorInstallerMaintainerService Provider
Septic CheckL262402/21/2026320-983-2447 6074 Keystone Rd, Milaca MN 56353YesYesYesYes
Service Provider Email: info@septiccheck.com

Monitoring Requirements

Monitoring Requirements:
ParameterEffluent LimitsFrequencyLocation
*Design Flow (gpd)300 GPDMonthlyFlow Meter
*Ponding/Surfacing in Soil TreatmentNone AllowedAnnuallyDrainfield
CBOD5 (mg/L)<10 mplAnnuallyPump Tank
TSS (mg/L)15 mplAnnuallyPump Tank
Monitoring Requirements Comments:
Monitoring will be done by George Rowell

Maintenance Requirements

Maintenance Requirements:
System ComponentMaintenanceFrequency
*Septic Tank/Trash TankClean filtersAnnually
*Pump Tank and ControlsCheck and calibrateAnnually
Advanced Treatment ProductCheck functionalityAnnually
*Soil Treatment and DispersalCheck for surfacing/pondingAnnually

Terms

Monitoring Protocol
  • Aitkin County Environmental Services authorizes the Permittee to operate a wastewater treatment and dispersal system at the address named above in accordance with the requirements of this operating permit, attached Management Plan and contract with the Service Provider/Inspector.

    This permit is effective on the issuance date identified above. This permit and the authorization to treat and disperse wastewater shall expire on the expiration date identified above. The Permittee is not authorized to discharge after the above date of expiration. The Permittee shall submit monitoring information on forms as required by Aitkin County Environmental Services no later than thirty (30) days prior to the above date of expiration for operating permit renewal. This permit is not transferable.

    The owner is required to obtain the services of a Minnesota Pollution Control Agency (MPCA) licensed and trained: 1) Service Provider or Inspector to provide ongoing system operation, maintenance, and monitoring and 2) Maintainer to pump the system's sewage tanks and components. The owner is responsible to provide the name of the Service Provider or Inspector business prior to the issuance of this operating permit. The owner has secured the services of [Name of Service Provider or Inspector] as the Service Provider or Inspector for this system. The Service Provider or Inspector is hereby authorized to provide the required monitoring data and routine maintenance service records to Aitkin County Environmental Services.

    [For systems that generate high strength wastewater, the following items should be added to the operating permit: 'If there is a change of use within the facility (i.e., change in menu, increase in food capacity, change in water use fixtures, etc.), the permittee is required to notify Aitkin County Environmental Services and the Service Provider before any changes occurs. Changes to the facility that could potentially impact performance of the wastewater treatment and dispersal system shall not take place until appropriate evaluation has been completed.']

    I hereby certify with my signature as the Permittee that I understand the provisions of the wastewater treatment and dispersal system operating permit including maintenance and monitoring requirements. I agree to indemnify and hold Aitkin County harmless from all loss, damages, costs and charges that may be incurred by the use of this system. If I fail to comply with the provisions of this operation permit, I understand that penalties may be issued. If I sell this property during the life of the permit, I will inform the new owner(s) of the permit requirements and the need to renew the operating permit.

Contingency Plan
  • In the event the wastewater treatment system does not meet required performance requirements as contained in this operating permit, the owner shall notify Aitkin County Environmental Services within thirty (30) days of receiving non-compliant information. The owner is responsible to obtain the services of a Minnesota Pollution Control Agency (MPCA) licensed Service Provider or other qualified practitioner to complete the required corrective measures

Authorization
  • Any sampling and laboratory testing procedures shall be performed in accordance with the proprietary treatment product's protocol, Standard Methods, and at a Minnesota Department of Health approved laboratory. Results shall be submitted to the permitting authority at: Aitkin County Environmental Services, 307 2nd St NW, Room 219, Aitkin, MN 56431 no later than the expiration date listed.

Invoice #59380 (02/02/2024)

Charge Cost Quantity Total
Non-Taxable
added 02/02/2024 1:12 PM

$150.00 x 1 $150.00
Grand Total
Total $150.00
Payment 02/02/2024$150.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantDavid & Nancy Claussen - 02/02/2024 1:13 PM - witnessed by Connor Plagge
162d49de6f33248bb4efdf73d34fbc1a
191a5e10c430de4de189dfbd6e223419
 
#1 Planning & ZoningConnor Plagge - 02/02/2024 1:14 PM
f37d092591dec6374ea2239a3a37f976
f1688dd116dc2b037bbf8b31fc91240a
 
Application has been approved. All signatures have been obtained.
Public Notes:
7.2.12 ok to move to a 5 yr renewal per Pete.
4.5.12 received maintenace from Septic Check. Recommended renewal to every 5 yrs or elimated.
2.24.12 paid renewal CK#6722, receipt 173061.
11.9.11 second letter sent.
Renewal sent 7.1.11 -kk
Next renewal 2011
Letter sent 6/22/09
Cal from North Star Builders called 7/7/09 said needed a couple days to get the readings from George Rowell due to health issues.
Received the reading from George Rowell on 08/19/09; looking for renewal payment.
Renewal letter sent 09/16/09.
Wants to renew out 2 years till 2011
Attachments:
    Expiration Date: 09/30/2022
    Internal Notes:
    Attachments: