Land Use Application Permit # 47158, App. # App-2022-009107, UID # 205698
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
Tom Betley
Phone:
(612770 - 1636
Email Address:
tom.betley@gmail.com
Mailing Address:
32728 353rd Pl
aitkin mn 56431
Are you the Property Owner? Yes

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
24-0-021900NORDLAND TWPS:11 T:46 R:26RDWLADIMIRAF LAKE (SECTION 10)BETLEY, TOMBETLEY, TOM
Enter directions to the property (if no property address assigned):
47 to county 17. driveway entrance is right before sissabagamah creek.  long driveway approx 1/2 mile in to building site

Project Checklist

1.) Is the property zoned Shoreland? Yes
3.) Are there any wetlands or lowlands on/near the project site? Yes
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
No
6.) Are you applying to install a new septic system? Yes

Septic Type

Select the type of septic you are applying for:
Residential Mound (Type 1)

Design Information

Attach Septic Design & Management Plan:
Septic Designer:
None

Operating Permit

Attach the Operating Permit Application & Operating Permit Maintenance Contract:

Installer

Self Install or Licensed Install: Licensed Septic Installer
Licensed Installer Name:
None
Installer License # : 4022

Project Description

Please describe your proposed project:
proposing to build Approx 38x88 3 bedroom house with bonus room above attached 38x27 garage(that may become 4th bedroom - thus 4 bedroom design for septic).  Slab only no basement.
What is the height of your structure? 18 Feet

Project Type

Item 1 - Structure Type: New Residence incl. attached decks/porches/garages
Item 1 - Size: 4375 ft2

Shoreland Data

Setback distance from Ordinary High Water Level to the proposed construction? (closest point) 105 Feet
Will the proposed structure(s) be less than 35 foot maximum height? Yes
Are you constructing a walkout basement? No
If you are building an accessory structure, will there will be a loft or second story? No

Natural Landscape Protection Plan

Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? Yes
(If yes, please attach plan):
How many cubic yards of fill or excavation will be done on the property? 160 CuYd
How close to the property line will any fill be placed or any excavation be done? 100 Feet
What percent slope of the land currently exists on the project site? .101 % slope
Select the erosion control methods that will be used throughout and after your project:
(Check all that apply)
6.) What will be done after construction to control
erosion?
restore grass that will be removed during construction

Site Plan

Attach Site Plan:
Is the site staked and ready for inspection? Yes

Additional Info

Additional info:
(optional)
Septic Design has wrong PID  it should be 24-0-021900 (he put 21800) Please call me when on site with questions.  If I am not on site I am only 5 minutes away.

Terms

Land Use/Septic Terms & Conditions
  • All appropriate permit fees must be paid in full prior to any necessary review(s) of application.

  • It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.

  • The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.

  • Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).

  • All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.

  • Permit fees are non-refundable after a permit has been approved.

  • The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.

  • Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."

  • Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.

  • Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.

  • Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.

  • I acknowledge that by submitting this application, the application and its attachments are public information.

Invoice #55482 (06/27/2022)

Charge Cost Quantity Total
Non-Taxable
added 06/27/2022 2:01 PM

$550 Flat Fee

$550.00 x 1 $550.00
added 07/21/2022 9:28 AM

$150 Flat Fee

$150.00 x 1 $150.00
added 07/21/2022 9:28 AM

$400 Flat Fee

$400.00 x 1 $400.00
Grand Total
Total $1,100.00
Payment 06/27/2022$900.00
Payment 07/21/2022$200.00
Due$0.00

Approvals

ApprovalSignature
ApplicantTom Betley - 07/21/2022 7:55 AM
c5636c51455841a35b67e1bcfa87b21e
39af59c294278df7505805aa000564f4
#1 Adminstrative Approval GroupHenry Egland - 07/28/2022 1:19 PM
a1ce2f589ab0d82ac3c6f26785f4f147
ac5e00daa1edf1e0a0749c044bd58358
#2 Inspector GroupHenry Egland - 07/28/2022 1:19 PM
1135ab12605be59a4fdf212d35ba71ab
a40c8559ba3a0e9955e19fd0252f7188
#3 Level Three Final ActionSarah McMillan - 07/28/2022 2:30 PM
7ee13ff1645dca97becf650d0441be19
c978d8562af780079088c9a82756b94b
Application has been approved. All signatures have been obtained.

Public Notes

Text:
Permit #47158
Approved for 4375 sq/ft residence and 4 bdrm Type III mound septic with operating permit #789
File(s):

Admin Checklist

Date application was complete: 06/27/2022
Review started by: Henry Egland
Zoning District of project location: Shoreland
Required OWHL setback distance:
"Other" OHWL setback distance is:
Project located in the floodplain? No
Base Flood Elevation:
Lowest Floor Elevation:
Is an after construction elevation certificate required?
Property line setbacks appear to be met? Yes
Road R-O-W setbacks appear to be met? Yes
Bluff setbacks appear to be met? N/A
Septic Tank setback appears to be met with/without an engineer's report? Yes
Septic Drainfield setback appears to be met with/without an engineer's report? Yes
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot?
Is this After-The-Fact? No

Inspector Checklist

Zoning Inspector: Henry Egland
Attach necessary inspection forms/photos:
Notes:
All setbacks were met. Silt fence needs to be trenched in.
Was an onsite conducted for this application? Yes