OneGov
App. Status: ApprovedAitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
Contact Information
Enter Applicant Contact Information: |
|
||||||||||||||||||||||||||||||||
Are you the Property Owner? | No |
Property Owner Contact
Property Owner Email: | paquettedandb@yahoo.com | ||||
Property Owner Phone: |
|
Property Location
Property Location: |
|
Enter directions to the property (if no property address assigned): | head north from Mcgregor to County road 14. Head east to County road 40 head south and turn left on 170th place follow until you hit the T and then turn left on 510th lane follow this to the end and turn right onto a state timber road which is actually the owners driveway. Follow this all the way to the end and you will come to their home. The site for the structure and sewer is just past the home. |
Project Checklist
1.) Is the property zoned Shoreland? | Yes |
3.) Are there any wetlands or lowlands on/near the project site? | No |
4.) Will the structure(s) be used for commercial purposes? | No |
5.) Is there an existing septic system on the property? (Outhouse/Privies are also considered septic systems) |
Yes |
6.) Are you applying to install a new septic system? | Yes |
Existing Septic Status
Do you have a Certificate of Compliance, Certificate of Installation, Design for a new system, or does your project fall under Exemption A or B above? | Yes |
Septic Type
Select the type of septic you are applying for: | Residential Bed (Type 1) |
Design Information
Attach Septic Design & Management Plan: | |
Septic Designer: |
None
|
Installer
Self Install or Licensed Install: | Licensed Septic Installer |
Licensed Installer Name: |
None
|
Project Description
Please describe your proposed project: | 36x48 accessory structure with 14' sidewalls and a new septic for the residence |
What is the height of your structure? | 25 Feet |
Project Type
Item 1 - Structure Type: | Accessory Building |
Item 1 - Size: | 1728 ft2 |
Shoreland Data
Setback distance from Ordinary High Water Level to the proposed construction? (closest point) | 150 Feet |
Will the proposed structure(s) be less than 35 foot maximum height? | Yes |
Are you constructing a walkout basement? | No |
If you are building an accessory structure, will there will be a loft or second story? | No |
Natural Landscape Protection Plan
Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? | No |
How many cubic yards of fill or excavation will be done on the property? | 175 CuYd |
How close to the property line will any fill be placed or any excavation be done? | 100 Feet |
What percent slope of the land currently exists on the project site? | 8 % slope |
Select the erosion control methods that will be used throughout and after your project: (Check all that apply) |
|
6.) What will be done after construction to control erosion? |
Natural regeneration |
Site Plan
Attach Site Plan: |
|
Is the site staked and ready for inspection? | Yes |
Terms
All appropriate permit fees must be paid in full prior to any necessary review(s) of application.
It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.
The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.
Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).
All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.
After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.
Permit fees are non-refundable after a permit has been approved.
The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.
Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."
Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.
Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.
Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.
I acknowledge that by submitting this application, the application and its attachments are public information.
Invoice #55420 (06/18/2022)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 06/18/2022 4:22 PM $300 Flat Fee |
$300.00 | x 1 | $300.00 |
added 06/27/2022 3:25 PM $300 Flat Fee |
$300.00 | x 1 | $300.00 |
Grand Total | |||
Total | $600.00 | ||
Payment 06/18/2022 | $600.00 | ||
Due | $0.00 |
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | online submittal - 06/27/2022 3:26 PM - witnessed by Kim Burton 05369517e034e98d8bce8cfb43d02144 ab01530ff1fed46048f6e9e508839cbc | |
#1 Adminstrative Approval Group | Molly Oestreich - 06/23/2022 10:06 AM f7c779b0626d8f02593db42be6ef4cc8 49c5a16b51aded5c0edc03bd6913ab9a | |
#2 Inspector Group | Molly Oestreich - 06/28/2022 1:54 PM 1f9a4de0d40ae31fd23f7127f38c29d9 2fc6e0c59bfcb1f181fd2490bcde110f | |
#3 Level Three Final Action | Sarah McMillan - 06/29/2022 9:06 AM 1709b074983de5f0a1598fe47a273ce8 0115d62b6fc8078386678d591c4bd072 |
Text: | Permit #47054 Approved for a 1728 sq ft accessory structure & a 3 bdrm Type I pressure bed septic. Applicant selected mound - refund $50 issued 7/6/22 KB |
File(s): |
|
Text: | $50 to be refunded KB Applicant selected mound septic rather than bed |
File(s): |
Date application was complete: | 06/18/2022 |
Review started by: | Connor Plagge |
Zoning District of project location: | Shoreland |
Required OWHL setback distance: | 150 ft. |
"Other" OHWL setback distance is: | |
Project located in the floodplain? | No |
Base Flood Elevation: | |
Lowest Floor Elevation: | |
Is an after construction elevation certificate required? | |
Property line setbacks appear to be met? | Yes |
Road R-O-W setbacks appear to be met? | Yes |
Bluff setbacks appear to be met? | Yes |
Septic Tank setback appears to be met with/without an engineer's report? | Yes |
Septic Drainfield setback appears to be met with/without an engineer's report? | Yes |
Does impervious and building coverage appear to be met? | |
Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? | Yes |
Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot? | |
Is this After-The-Fact? | No |
Zoning Inspector: | Kevin Turnock |
SSTS Type: | Type I |
SSTS Design: | Pressure Bed/Seepage |
New or Replacement SSTS: | Replacement SSTS |
Design Flow: | 1-2,499 gpd |
# of bedrooms: | 3 |
Does this system require an Operating Permit? | No |
Operating Permit #: | |
Does this system belong to an other establishment? | No |
Is this a Cluster System? | No |
Attachments: |
Zoning Inspector: | Molly Oestreich |
Attach necessary inspection forms/photos: | |
Notes: | Approved for a 1728 sq ft accessory structure & a 3 bdrm Type I pressure bed septic. |
Was an onsite conducted for this application? | Yes |
Self Install? | |
Installer Name: |
None
|
New Tanks: | 1 |
Existing Tanks: | 0 |
Date of Final Inspection: | 07/20/2022 |
Attach Final Certificate of Installation: |
|
Low Interest Loan or SSTS Grant project? |