Land Use Application Permit # 47075, App. # App-2022-009089, UID # 205579
App. Status: Approved
Aitkin County Planning & Zoning / Environmental Services
307 Second St. NW Room 219
Aitkin, MN 56431
Phone: 218-927-7342
Fax: 218-927-4372
Email: aitkinpz@aitkincountymn.gov
 

Contact Information

Enter Applicant Contact Information:
Name:
Charity Ann Alich
Phone:
(612280 - 9050
Email Address:
caalich@gmail.com
Mailing Address:
2108 136th LN NE
Ham Lake MN 55304 7001
Are you the Property Owner? Yes

Property Location

Property Location:
Property LocationLegal DescriptionProperty AttributesOwner InformationTax Payer Information
Parcel NumberProperty AddressTownship or City NameLegal DescriptionPlat NameSection-Township-RangeLake ClassLake NameOwner Name(s)Taxpayer Name(s)
20-1-074400MACVILLE TWPJAMS CORNER LOTSS:15 T:51 R:26ALICH, CHARITYALICH, CHARITY
20-1-07450036076 610th St
HILL CITY, MN 55748
MACVILLE TWPJAMS CORNER LOTSS:15 T:51 R:26ALICH, CHARITYALICH, CHARITY
Enter directions to the property (if no property address assigned):
North on HWY 169 
turn left on 610th ST
2nd driveway on right

Project Checklist

1.) Is the property zoned Shoreland? Yes
3.) Are there any wetlands or lowlands on/near the project site? Yes
4.) Will the structure(s) be used for commercial purposes? No
5.) Is there an existing septic system on the property?
(Outhouse/Privies are also considered septic systems)
Yes
6.) Are you applying to install a new septic system? No

Existing Septic Status

Do you have a Certificate of Compliance, Certificate of Installation, Design for a new system, or does your project fall under Exemption A or B above? Yes

Project Description

Please describe your proposed project:
I am proposing to place a 24x53 single story modular home on 4 course crawl space foundation.  The build includes brining in approximately 400-600 yards of fill/top soil to bring the foundation slab to the BFE.
What is the height of your structure? 11 Feet

Project Type

Item 1 - Structure Type: New Residence incl. attached decks/porches/garages
Item 1 - Size: 1343 ft2

Shoreland Data

Setback distance from Ordinary High Water Level to the proposed construction? (closest point) 105 Feet
Will the proposed structure(s) be less than 35 foot maximum height? Yes
Are you constructing a walkout basement? No
If you are building an accessory structure, will there will be a loft or second story? No

Natural Landscape Protection Plan

Will there be any vegetation removal, earth moving, or fill placed in the Shore Impact Zone, Bluff Impact Zone or on a Steep Slope? No
How many cubic yards of fill or excavation will be done on the property? 600 CuYd
How close to the property line will any fill be placed or any excavation be done? 100 Feet
What percent slope of the land currently exists on the project site? 4 % slope
Select the erosion control methods that will be used throughout and after your project:
(Check all that apply)
6.) What will be done after construction to control
erosion?
Black dirt and seed, with straw covering to start

Site Plan

Attach Site Plan:
Is the site staked and ready for inspection? Yes

Terms

Land Use/Septic Terms & Conditions
  • All appropriate permit fees must be paid in full prior to any necessary review(s) of application.

  • It shall be a violation of the Aitkin County Zoning Ordinance to commence construction before the permit application is approved by Aitkin County.

  • The septic installer shall notify Aitkin County Environmental Services a minimum of twenty-four (24) hours before the covering of any portion of the septic installation. Changes from the approved septic design will require approval by the County prior to construction.

  • Zoning permits and Subsurface Sewage Treatment System permits are valid for one (1) year (unless the sewage permit is to upgrade an Imminent Threat to Public Health or Safety system, which is then valid for ten (10) months).

  • All corners of the proposed structure(s) need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • If property lines are not clearly marked and visible, then they need to be staked with visible flags, ribbon, or lathes prior to onsite inspection by Aitkin County.

  • After a complete application is submitted and reviewed, an on-site inspection may be conducted; a permit may be issued describing the proposed construction that may take place on the property. Changes to a project may require a permit application to be resubmitted.

  • Permit fees are non-refundable after a permit has been approved.

  • The landowner or authorized agent may make application for a zoning permit agreeing to do such work in accordance with all Aitkin County Ordinances. The landowner or authorized agent agrees that the application, site plan, and all other attachments submitted herewith are true and accurate and shall become a part of the permit. The landowner or authorized agent agrees that, in making application for a zoning permit, the landowner grants permission to Aitkin County, at reasonable times, to enter the property to determine compliance of the application with applicable Local, County or State Ordinances or Statutes. It is the applicants sole responsibility to contact other Local, County or State agencies to ensure the applicant has complied with all relevant Local, County or State Ordinances or Statutes.

  • Applicants acknowledge that they are in compliance with MN Statute 326.121 subd 1 which states "The State Building Code is the standard that applies statewide for the construction, reconstruction, alteration, repair, use of buildings and other structures of the type governed by the code."

  • Applicants acknowledge that they are in compliance with MN Contractor Licensing laws per MN Statute 326B.85.

  • Applicants are responsible for getting all applicable entrance permits from the appropriate road authority.

  • Defining and staking the property lines, road right-of-ways, septic sites, and wells are the responsibility of the property owner. In some cases, a registered survey may be required to verify setbacks before granting a permit.

  • I acknowledge that by submitting this application, the application and its attachments are public information.

Invoice #55370 (06/23/2022)

Charge Cost Quantity Total
Non-Taxable
added 06/12/2022 8:42 PM

$400 Flat Fee

$400.00 x 1 $400.00
Grand Total
Total $400.00
Payment 06/23/2022$400.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantCharity A. Alich - 07/01/2022 2:38 PM
78a8d068e1a3445c565a44019e17332e
c93734bdbe50d536611a3c0d68b9fa3d
 
#1 Adminstrative Approval GroupHenry Egland - 07/01/2022 2:49 PM
bc6a64b62bd23477da1fab818cf5576d
835b959fbfc1822d548c1f92b4d041e5
 
#2 Inspector GroupHenry Egland - 07/01/2022 2:51 PM
09a335f910316c68887753fd1dc56a58
664b4d9679500037744b82f2fcb7a7f6
 
#3 Level Three Final ActionSarah McMillan - 07/01/2022 3:26 PM
ff21c5038591604ed913a7edb7bdf0ea
1347051f7f9bfdce8c3c167d86a3a3de
 
Application has been approved. All signatures have been obtained.
Text:
Permit #47075
Approved for 1343 sq/ft residence.
Post construction elevation certificate required
Condition: Silt fence to be installed on wetland boundary until vegetation is established.
File(s):
Text:
File(s):
    Date application was complete: 06/23/2022
    Review started by: Henry Egland
    Zoning District of project location: Shoreland
    Required OWHL setback distance:
    "Other" OHWL setback distance is:
    Project located in the floodplain? Yes
    Base Flood Elevation: 1273.5
    Lowest Floor Elevation: 1274.5
    Is an after construction elevation certificate required? Yes
    Property line setbacks appear to be met? Yes
    Road R-O-W setbacks appear to be met? Yes
    Bluff setbacks appear to be met? N/A
    Septic Tank setback appears to be met with/without an engineer's report? Yes
    Septic Drainfield setback appears to be met with/without an engineer's report? Yes
    Is the parcel a Lot of Record before 1-21-92 or have alternate sites been identified? Yes
    Is this New Construction on a previously undeveloped lot or Redevelopment added to a developed lot?
    Is this After-The-Fact? No
    Zoning Inspector:
    SSTS Type:
    SSTS Design:
    New or Replacement SSTS:
    GPD:
    # of bedrooms:
    Does this system require an Operating Permit?
    Operating Permit #:
    Does this system belong to an other establishment?
    Is this a Cluster System?
    Attachments:
      Zoning Inspector: Henry Egland
      Attach necessary inspection forms/photos:
      Notes:
      Structure site met all setbacks.
      Was an onsite conducted for this application? Yes
      Self Install?
      Installer Name:
      None
      New Tanks:
      Existing Tanks:
      Date of Final Inspection:
      Attach Final Certificate of Installation:
        Low Interest Loan or SSTS Grant project?
        Powered by